Jquery highlight search text in div

11kV, 630A to 1250A, 26.3kA Indoor Vacuum Circuit Breaker Panel

Indoor VCB Panel:

Product overview

The legendary Indoor Vertical Isolation VCB is a prominent device in Indian Railways and various utilities. The vertical isolation and horizontal draw-out truck provides a higher degree of compactness and assures more ground area than horizontal isolation trucks. The product has a very high degree of rigidity and the best class control solutions.

Technical Details

  • Model No : 11KV: MV V12 I, 33kV : MV V36 I.
  • Rated Voltage & Rated Current :12kV & 36kV, 630A up to 2000A.
  • Frequency : 50Hz.
  • Short Time Withstand Current And Duration: 26.3kA/3Sec.
  • Insulation Level: 11kV : 28kV / 75kV Peak,33kV : 70kV / 170kV Peak.
  • Closing / Tripping Coil Voltage: 24VDC to 220VDC.
  • Spring Charge Mechanism: 230VAC.
  • Breaker Standard: IEC 62271 – 100, IS13318.
  • Degree of Protection: IP4X & 5X.

Outdoor VCB Panel

Product overview

The KIOSK is specifically made for unattended substations in the outside distribution network. It is an independent vacuum switchgear system that has an integrated self-driven independent control supply for CB self-tripping and closure. The product has all the necessary components for protection, control, metering, and SCADA compatibility.

The product is available in two basic designs

  • Roof bushing type with incoming & outgoing through roof bushings (Rated Voltage: 12 & 36 kV).
  • Line up type with incoming through bottom, rear / side cable entry & outgoing through bus bar / cables (Rated Voltage:12 kV).

Technical Details

  • Model No : 11KV: MV V12 I.
  • Rated Voltage & Rated Current :12kV, 630A up to 2000A.
  • Frequency : 50Hz.
  • Short Time Withstand Current And Duration: 26.3kA/3Sec.
  • Insulation Level: 11kV : 28kV / 75kV Peak,33kV : 70kV / 170kV Peak.
  • Closing / Tripping Coil Voltage: 24VDC to 220VDC.
  • Spring Charge Mechanism: 230VAC.
  • Breaker Standard: IEC 62271 – 100, IS13318.
  • Degree of Protection: IP4X & 5X.
11kV &33kV,630A to 1250A,13.1kA Porcelain Clad Vacuum Circuit Breaker

Product overview:

In the utilities distribution market, it is a highly sought-after product. The device has a rated voltage of 12 kV to 36 kV and is specifically made for outdoor use. Throughout the years, the device has had periodic design improvements that provide you a sense of satisfaction about safety and dependability.

Technical Details

  • Model No : 11KV: MV V12 I, 33kV : MV V36 I.
  • Rated Voltage & Rated Current :12kV & 36kV, 630A up to 2000A.
  • Frequency : 50Hz.
  • Short Time Withstand Current And Duration: 26.3kA/3Sec.
  • Insulation Level: 11kV : 28kV / 75kV Peak,33kV : 70kV / 170kV Peak.
  • Closing / Tripping Coil Voltage: 24VDC to 220VDC.
  • Spring Charge Mechanism: 230VAC.
  • Breaker Standard: IEC 62271 – 100, IS13318.
  • Degree of Protection: IP4X & 5X.
11kV, 630A, 25kA Ring Main Gear (Both Indoor & Outdoor)

Product overview:

Furthermore, a single-number tee-off vacuum circuit breaker with protective devices and a two-number load break switch can be added to the Ring Main Unit. Distribution switchboards, transformer substations, ring distribution networks, and high-voltage connections to commercial and industrial sites are just a few of the many uses for this incredibly versatile unit. With remote operation, the devices are designed to meet the needs of the user in terms of connection, supply, protection, and sectionalization.

Circuit Breaker:

The three vacuum interrupters that make up the CB are rated for fault-make and fault-break. By connecting the CB in series with the off-load disconnector/selector switch, the outgoing wire can be earthed.

Ring Switch:

These are fault-make load break switches that use a single break. They have three positions: "ON," "OFF," and "Earth."

Technical Details

  • Model No : 11KV: MV V12 I, 33kV : MV V36 I.
  • Rated Voltage & Rated Current :12kV & 36kV, 630A up to 2000A.
  • Frequency : 50Hz.
  • Short Time Withstand Current And Duration: 26.3kA/3Sec.
  • Insulation Level: 11kV : 28kV / 75kV Peak,33kV : 70kV / 170kV Peak.
  • Closing / Tripping Coil Voltage: 24VDC to 220VDC.
  • Spring Charge Mechanism: 230VAC.
  • Breaker Standard: IEC 62271 – 100, IS13318.
  • Degree of Protection: IP4X & 5X.
11kV, 630A, 25kA Load Break Switch Panel (Both Indoor & Outdoor)

Technical Details

  • Model No : MV V12 LBS.
  • Rated Voltage & Rated Current :12kV & 36kV, 630A up to 2000A.
  • Frequency : 50Hz.
  • Short Time Withstand Current And Duration: 26.3kA/3Sec.
  • Insulation Level: 28kV / 75kV Peak.
  • Breaker Standard: IEC 60265/ IS 9920.
  • Degree of Protection: IP4X & 5X.
11kV, 630A, 25kA Off Load Isolator

Technical Details

  • Model No : MV V12 OI.
  • Rated Voltage & Rated Current:12kV, 630A Up to 2000A.
  • Frequency : 50Hz.
  • Insulation Level: 28kV / 75kV Peak.
  • Breaker Standard: IS 9920.


Compact Substation

Product overview:

USS is a prefabricated secondary substation that combines low voltage switchgear, minimum voltage & switchgear, distribution transformer, and related protection and metering components in a single, compact unit that complies with standards.

Technical Details

  • Model No : USS V12 O.
  • Rated Voltage & Rated Current:12kV, 630A Up to 2000A.
  • Frequency : 50Hz.
  • Insulation Level: 28kV / 75kV Peak.
  • IEC 62271-202, IEC 1330(1995) and IS 14786:2000 Standards.
  • Breaker Standard: IS 9920.
Low Voltage switchgear panels

Low Voltage switchgear panels

Product Range:

LV panels, MCC, PCC, APFC, VFD, SOFTSTARTER Panels & All types of Distribution boards.

Standards:

IEC-60439 Part 1&2, IS-8623 Part 1&2 with Customized design.

Fault level:

UP TO 80kA with Al / Cu Bus bars.


PCC panels

  • Ratings : From 630A to 6000A (Draw out / Fixed Type).
  • Construction : Single front, Single / Two Tier Arrangement.

MCC panels


  • Construction: Single / Double Front, Draw-out / Fixed Type with Microprocessor based along with VFD, Softstarters advanced motor protection relays.
  • For wide range of motor ratings.

APFC panels


For the purpose of achieving unity or nearly unity power factor, we develop Automatic Power Factor Control Panels. Our APFC Panels' power factor controller keeps an eye on reactive power, which ultimately contributes to energy conservation.


DB panels

Customers greatly value the Distribution Board's qualities, which include dependable performance, robust corrosion, and durability.

Features

  • Correction to Unit Power Factor
  • Modular design which allows easy handling by the user
  • Designed to minimize installation time & cost

VFD panels

The industry's illustrated parameters are met by these products. These instrumentation panels are available to our esteemed clients in a variety of technological parameters based on their needs.

Features

  • User-friendly operation
  • Minimum maintenance
  • Longer service life
  • Efficient performance

Soft Starters Panels

We are providing an excellent selection of Soft Starter Panels to satisfy the various needs of our customers. The following characteristics of this line of soft starter panels have earned it widespread praise from customers.

End Users

Major Clients

  • Danway
  • Schneider Electric
  • ABB

OUR CUSTOMERS